TRS1000E RF Switch Module

TRS1000E RF switch module with two path RF signal input ,one path RF signal output are widely used in the 1550 nm, 1310 nm ring-network system ...

Current position:HOME > HFC

TRS1000E RF Switch Module


Overview        TRS1000E RF switch module with two path RF signal input ,one path RF signal output are widely used in the 1550 nm, 1310 nm ring-network system.Users can set the switching threshold.with two path RF input signal detection and judgment, if radio frequency signal level is lower than or exceeds the threshold, the switch will set to switch on its own.
       In the case of two way RF signals are normal,products support switching manually RF channel , and switching on the front panel or remote network management forcefully. At the same time ,remote network management provides a real-time monitoring. Features         Bandwidth:5 ~ 1000 MHZ
        Low insertion loss;
        High isolation and shot switching time
        Supporting automatic or manual mode switching
        Optical power automatic switching user are adjustable
        Supporting displaying each channel ‘s average power and total power of RF signal through the?master-control?interface
        Perfect protection for circuit
        Supporting hot plug
        Input optical power range is large
        Possessing RF monitoring function
        Supporting optical input power and output frequency double detection and judgment
        Reporting and displaying all kinds of working status parameters
        Open network management interface follows the national network management standard, SCTE HMS network management standards with direct condition monitoring and fault diagnosis through Ethernet. Technical Specifications

No

Item

Unit

Parameters

Remark

1

Frequency range

MHz

51000

2

Input reflection loss

dB

≥16

3

Output reflection loss

dB

≥16

4

Isolation of input ports

dB

≥70

5

Isolation between input and output ports

dB

≥70

6

Insertion loss

dB

≤2.5

7

Flatness

dB

±0.75

8

Maximum group delay 

ns

5

9

RF switching time

ms

15

10

RF input impedance

Ω

75

11

Suggested input level range

dBuV

8010659 path PAL signal

12

RF switching threshold

dBuV

8559 path PAL signal

Others are optional

13

RF switch working life

Time

1,000,000min

14

Module loss

W

1

15

Control mode

Automatically or manually

16

Input and output optical port

FC/APC or SC/APC

17

Operating temperature

oC

-5+55

18

Storage temperature

oC

-30+70

19

Relative humidity

5%95%

Non-condensation

20

Dimension

mm

25.5×126×392.5


 